4-3 Detection Settings (Func)

4

Set

tings
for Ad

van
c

ed Fu

nct
ion
s

4-14

- Digital Laser Sensor LV-N10 Series User's Manual -

Area detection mode

In this mode, the output signal is
delivered (in N.O. condition) if the
received light intensity is in the area
defined by Hi (upper limit) and Lo
(lower limit).

• Output-1 can be configured to be ON (N.O.) or OFF (N.C.) when the

received light intensity is above the Lo and under the Hi settings.

"Output Switch (L-on/D-on)" (page 3-4)

• Area detection can be set just for output-1 scale. Output-2 scale operates

according to the "Output 2 detection mode".

"Detection Mode for Output2" (page 4-33)

Always ensure that "upper limit setting value > lower limit setting
value". If "upper limit setting value

lower limit setting value", the

received light intensity will always be output outside the Hi and Lo
range.

Refer to page 4-2 "Detection Settings (Func)" for setting methods.

Control output
in N.O. condition

Control output
in N.C. condition

Hi (Upper limit

setting value)

Lo (Lower limit

setting value)

ON

0

OFF

ON

OFF

Reference

Point