Mounting and adjusting the sensor head, Lv-nh32/nh35/nh37/nh42/nh62/s63, Lv-nh100/nh110/nh300 – KEYENCE LV-N10 Series User Manual
Page 20: Mounting and adjusting the sensor head -6
2
In
st
al
la
tio
n
a
nd
Co
nnec
ti
on
2-6
- Digital Laser Sensor LV-N10 Series User's Manual -
2-3
Mounting and Adjusting the Sensor Head
Use the included mounting bracket.
The tightening torques are shown below.
LV-NH32/NH35/NH37/NH42/NH62: 0.3 N
·m
LV-S63: 0.6 N
·m
LV-NH32 spot diameter adjustment
Turn the focus ring to adjust the size of the spot diameter.
After adjusting, tighten fix the focus lock screw.
Using the following optional brackets to mount the unit.
LV-NH100/NH100: Vertical mounting bracket (LV-B101) or horizontal mounting bracket (LV-B102)
LV-NH300: Vertical mounting bracket (LV-B301) or horizontal mounting bracket (LV-B302)
Vertical mounting bracket (LV-B101/LV-B301)
Included: Mounting bracket 2 pcs., plate nut 2 pcs., M3 × 18 screws 4 pcs.
1
Mount as shown on the right.
Horizontal mounting bracket (LV-B102/LV-B302)
Included: Mounting bracket 2 sets, plate nut 2 pcs., M3 × 18 screws 4 pcs.
1
Mount as shown on the right.
Insert the plate nut* between the
sensor section and mounting bracket.
* When using LV-NH100/NH110, the long plate nut is used for the transmitter, and the
short plate nut for the receiver.
When using LV-NH300, the long plate nut is used for the receiver, and the short
plate nut for the transmitter.
LV-NH32/NH35/NH37/NH42/NH62/S63
LV-NH100/NH110/NH300