background image

4-2 Basic Settings

4

Set

tings
for Ad

van
c

ed Fu

nct
ion
s

4-5

- Digital Laser Sensor LV-N10 Series User's Manual -

Percentage calibration

The setting value can be specified as a
percentage in respect to the current received
light intensity.

The percentage calibration target value can be
set in the range of "-99P" (-99%) to 99P (99%)
Default: -10P (-10%)

Sensitivity setting

1

In the desired reference state, press
the [SET] button.
Calibration is complete after the setting
value flashes momentarily, and then
stops (lights up).

• If the external input setting is set to "SEt" (external calibration input), peri-

odic percentage calibration is possible from external devices, enabling
stable detection even on workpieces having small sensitivity differences.

"External Input" (page 4-17)

• If the detection mode is set to "ArEA (area detection mode)", Hi and Lo

are set simultaneously according to the received light intensity.

(Example)
If the percentage calibration is set
to 10P (10%) when the reference
received light intensity is "100",
the Hi and Lo setting values will be
set as follows.
Hi setting value: 110
Lo setting value: 90

900

1000

Reference

Received light intensity

Setting example

When the percentage calibration
target value is set to "-10%".

Reference

Received

light intensity

Hi

110

100

90

Lo