Other calibration methods, Other calibration methods -16 – KEYENCE LV-N10 Series User Manual

Page 40

background image

3-3 Adjusting the Sensitivity

3

Ba
sic
Oper

ati
on

3-16

- Digital Laser Sensor LV-N10 Series User's Manual -

Percentage calibration

A setting value is established with a percentage in respect to the current received light
intensity. When used together with external calibration input, percentage calibration
can be performed from an external device, such as a PLC, allowing highly accurate
detection of transparent workpieces and small workpieces, etc.

Refer to

"Sensitivity Setting" (page 4-4) for details.

Zero shift calibration

This sensitivity setting performs the zero shift function and basic calibration (two-point
calibration / maximum sensitivity calibration / full auto calibration) simultaneously.
The lower of the received light intensity values specified at the time of sensitivity
setting will automatically be set to 0.

Refer to

"Sensitivity Setting" (page 4-4) for details.

Percentage calibration and zero shift calibration cannot be set with
channel 2 of the 2-output type models.

Other Calibration Methods

Point