Two-point calibration, Two-point calibration -12 – KEYENCE LV-N10 Series User Manual
Page 36

3-3 Adjusting the Sensitivity
3
Ba
sic
Oper
ati
on
3-12
- Digital Laser Sensor LV-N10 Series User's Manual -
Two-point calibration is the most basic method of sensitivity setting.
The setting value can be established by simply pressing the [SET] button once each
when a workpiece is present. and when it is absent.
1
Press the [SET] button once
when no workpiece is
present.
2
Press the [SET] button once
when a workpiece is present.
Calibration is complete after the
setting value flashes momen-
tarily, and then stops (lights up).
Press the
button to adjust
the setting value.
Step 1 or step 2 may be performed first.
When performing two-point calibration on channel 2 of the 2-output type,
set the channel switch to "2".
Two-point Calibration
Reference
If the difference between the 2 conditions is too small, "- - - -" flashes
after calibration is complete.
However, the setting value will still established.
Setting
value
Time
The setting value is set to the middle
of the values at which the [SET] button
was pressed first and pressed second.
Receiv
ed
lig
ht intensity
2
1