beautypg.com

Two-point calibration, Two-point calibration -12 – KEYENCE LV-N10 Series User Manual

Page 36

background image

3-3 Adjusting the Sensitivity

3

Ba
sic
Oper

ati
on

3-12

- Digital Laser Sensor LV-N10 Series User's Manual -

Two-point calibration is the most basic method of sensitivity setting.
The setting value can be established by simply pressing the [SET] button once each
when a workpiece is present. and when it is absent.

1

Press the [SET] button once
when no workpiece is
present.

2

Press the [SET] button once
when a workpiece is present.
Calibration is complete after the
setting value flashes momen-
tarily, and then stops (lights up).
Press the

button to adjust

the setting value.

Step 1 or step 2 may be performed first.
When performing two-point calibration on channel 2 of the 2-output type,
set the channel switch to "2".

Two-point Calibration

Reference

If the difference between the 2 conditions is too small, "- - - -" flashes
after calibration is complete.
However, the setting value will still established.

Setting
value

Time

The setting value is set to the middle
of the values at which the [SET] button
was pressed first and pressed second.

Receiv

ed

lig

ht intensity

2

1