beautypg.com

Installing sensor amplifiers, Mounting the sensor amplifier, Installing sensor amplifiers -2 – KEYENCE LV-N10 Series User Manual

Page 16: Mounting the sensor amplifier -2

background image

2

In

st

al

la

tio

n

a

nd
Co
nnec

ti

on

2-2

- Digital Laser Sensor LV-N10 Series User's Manual -

2-1

Installing Sensor Amplifiers

Mounting on a DIN rail

1

Align the claw at the bottom of the main body
with the DIN rail, as shown on the right.
While pushing the main body in the direction
of the arrow (1), push down in the direction of
arrow (2).

2

To release the amplifier, raise the amplifier
body in the direction of arrow (3) while push-
ing in the direction of arrow (1).

Installation on a wall

This method applies only when using the main unit independently. If the
main unit is connected with an expansion unit(s), use the method of mount-
ing on a DIN rail.

1

Mount the amplifier on the amplifier mount-
ing bracket (OP-73880, sold separately),
using the same manner as "Mounting on a
DIN rail".

2

Secure the unit with two M3 screws as
shown in the illustration.

Connecting multiple amplifiers

Up to 16 expansion units can be connected to 1 main unit. Note, however, that the 2-
output type is considered as 2 expansion units.

Mounting the Sensor Amplifier

(1)

(3)

(2)

Reference

OP-73880

Mount on DIN rail and install on metal surface when connecting
multiple amplifiers or mounting main units together.

WARNING