beautypg.com

Detection mode, Detection mode -8 – KEYENCE LV-N10 Series User Manual

Page 56

background image

4-3 Detection Settings (Func)

4

Set

tings
for Ad

van
c

ed Fu

nct
ion
s

4-8

- Digital Laser Sensor LV-N10 Series User's Manual -

The table below lists the detection modes that can be selected.

*1 In the DATUM mode, correction intervals can be set in the range of LEv1 to LEv3.

The default is LEv1.
Also, the warning output level can be set in the range of 0P (0%) to 100P (100%).
The default is 50P.

"Adjusting the correction interval" (page 4-12)

"Changing the warning output level" (page 4-13)

*2 This cannot be selected when LV-S31 is connected.

• Refer to

"Detection Mode for Output2" (page 4-33) for details on

the 2-output type channel 2 detection mode.

• Refer to

"Restrictions on Each Detection Mode" (page 6-8) for

restrictions on the sensitivity setting methods.

Detection Mode

Refer to page 4-2 "Detection Settings (Func)" for setting methods.

Display

Detection mode

Function

Reference

page

Std

Normal detection

Normal detection mode (Default)

-

dtM1

DATUM1 mode

*1 *2

The received light intensity when
there is no workpiece is always cali-
brated to "

100.0

", and the setting

value is also calibrated so that the set-
ting value and received light intensity
ratio is always constant.

4-9

dtM2

DATUM2 mode

*1

*2

The received light intensity when
there is no workpiece is always cali-
brated to "

.0

", and the setting value is

also calibrated so that the setting
value and received light intensity ratio
is always constant.

4-11

ArEA

Area detection mode

Detection is made only when the
received light intensity goes out of a
given range.

4-14

_|~d

Rising edge detection
mode

*2

Detection is made only when the
received light intensity increases.

4-16

~L_d

Falling edge detection
mode

*2

Detection is made only when the
received light intensity decreases.

4-16

Point