3-1 Quick Reference

3

Ba
sic
Oper

ati
on

3-3

- Digital Laser Sensor LV-N10 Series User's Manual -

Loading the

recommended set-

tings

15

Load the recommended settings.
(Recipe function)

1. Press and hold the [SET] button and [PRE-
SET] button.
2. Display the LoAd screen with the

(

)

button, and press the [MODE] button.
3. Select the recipe such as r-1 FALL with the

(

) button.

4. Press the [MODE] button to execute.

3-19

Initializing the set-

tings

16

Initializing (Restore to factory default
settings)

1. Press and hold the [SET] button and [PRE-
SET] button.
2. Press the [MODE] button while on the rSt

screen.
3. Select init with the

(

) button.

4. Press the [MODE] button to execute.

3-21

Displaying the out-

put 2 display

screen with the

2-output type

17

Switch to the output 2 display screen.

Set the channel switch to

.

* The output 2 sensitivity and advanced set-
tings can be modified in this state.

4-33

Switching to the

maximum received

light intensity

power mode

18

Adjust the power mode to the MEGA
mode.

Set the power select switch to

.

3-22

Preventing

incorrect

operations

19

Activating the key lock

Press and hold the [MODE] button and the

(

) button simultaneously.

3-23

20

Deactivating the key lock

Press and hold the [MODE] button and the

(

) button simultaneously.

3-23

21

Activating the password-protected key
lock

1. Press the

(

) button10 times while

holding down the [MODE] button.
2. Input the password with the

(

) button.

3. Press the [MODE] button to execute.

3-24

22

Deactivating the password-protected
key lock

1. Press the

(

) button 10 times while

holding down the [MODE] button.
2. Input the password with the

(

) button.

3. Press the [MODE] button to deactivate the
key lock.

3-24

Others

(Advanced

function settings,

etc.)

23

Setting the advanced functions

Press and hold the [MODE] button.

4-1

24

Setting to rescale at each preset exe-
cution so that analog output is "5 V"
output in respect to "100.0".

1. Press and hold the [MODE] button,

but-

ton and [SET] button simultaneously.
2. Press the [MODE] button once or twice.
3. Select "Pr-A PrST" with

(

) button, and

press the [MODE] button.

4-21

25

Switching the display to extended dis-
play or received light intensity hold
display, etc. (sub-display)

After setting the sub-display with the advanced
function settings, press the [MODE] button
twice.

4-22

26

Resetting the following values
* Received light intensity hold value
* Excess gain hold value
* Output when output 2 is in limit set-
ting detection mode
* Count value when output 2 is in
counter output mode

Press and hold the [MODE] button and [SET]
button.

4-24

4-34
4-35

Saving and

loading the

settings

27

Saving the settings (custom save)

1. Press and hold the [SET] button and [PRE-
SET] button.
2. Display the SAvE screen with the

(

)

button, and press the [MODE] button.
3. Select yES with the

(

) button.

4. Press the [MODE] button to execute.

4-38

28

Loading the settings (user reset)

1. Press and hold the [SET] button and [PRE-
SET] button.
2. Press the [MODE] button on the rSt screen.
3. Select USEr with the

(

) button.

4. Press the [MODE] button to execute.

4-39

Purpose

Description

Operation procedures

Reference