Basic settings, Power modes, Sensitivity setting – KEYENCE LV-N10 Series User Manual
Page 52: Basic settings -4, Power modes -4 sensitivity setting -4
4
Set
tings
for Ad
van
c
ed Fu
nct
ion
s
4-4
- Digital Laser Sensor LV-N10 Series User's Manual -
4-2
Basic Settings
The detection stability will increase when the response time is delayed.
You can select from the following 6 power modes.
The response time slows down in the order of hSP, FinE, turb, Supr, ULtr, MEGA.
* Cannot be selected when the LV-S31/S62/S63 sensor head is connected.
You can select from the following 3 sensitivity setting methods.
* Refer to the following 2 pages for details.
Power Modes
Refer to page 4-2 "Basic Settings" for setting methods.
Display
Power mode name
Response time
hSP
*
HIGH SPEED mode
80 øs
FinE
FINE mode
250 øs
turb
TURBO mode (Default)
500 øs
SuPr
SUPER mode
1 ms
ULtr
ULTRA mode
4 ms
MEGA
MEGA mode
16 ms
Sensitivity Setting
Refer to page 4-2 "Basic Settings" for setting methods.
Display
Sensitivity setting method
Reference
page
Std
Normal sensitivity setting (without correction) (Default)
SEtP
Percentage calibration
0SEt
Zero shift calibration