2. Move the cursor to an input number and select

ENABLE or DISABLE with the or ► button. The
default setting is ENABLE.

ENABLE; The unit accepts the sensor input.
DISABLE: The unit ignores the sensor input.
EXT: The highest priority is given to #8 port that the

unit ignores inputs to other ports when #8 port is

activated,

3, Repeat step 2 above until relevant ports are set.

470 SEQ. SCAN SETUP (Transmitter only)

The menu 430 presets a maximum of 8 video switches. The

sequential scan is a function that traces these video switch­
es in order, and only the Remote site unit (transmitter) is
controllable. The Control site can monitor these scanning
images in communication status. The Remote site can mon­
itor these images while it is in communication. This setup is
applied only to the transmitter,

1. Open the 470 SEQ. SCAN SETUP menu.

470 SEQ.SCAN SETUP

SEQ.SCAN
DWELL TIME
RESTART TIME

ON OPF

OSS {02S-30S)
060S

(010S-300S)

ti<-^:MOVE ESC:PRV

4.

Move the cursor to the SEQ.SCAN and select either ON

or OFF with the or ► button. The default setting is

OFF.

ON: Sequential scan enabled.
OFF: Disabled,

Move the cursor to DWELL TIME and enter a time dura­

tion with the numeric buttons. The time is in second to

monitor per point. The default setting is 5S.

02-30S: Set an appropriate time in second.

Move the cursor to RESTART TIME and select a time
duration with the numeric buttons. The time is in sec­

ond to restart the sequential scan after an interruption

made by a manual operation. The default setting is

60S.

010-300S: Set an appropriate time in second.

480 LOCK/MENU PASSWORD

This menu provides the unit with protection from accidental
use, or from use by unauthorized operator.

480 LOCK/MENU PASSWORD

481 LOCKl
482 MENU PASSWORDl

Tl:MOVE ENT;SELECT ESCiPRV

1. Open the 480 LOCK/MENU PASSWORD menu.

2. Move the cursor to 481 or 482 with the or ► button,

then press the ENTER.
The selected menu appears.

481 LOCK

MENU LOCK enables or disables the password protection

when opening the menu windows. Preset password is
entered in the 482 MENU PASSWORD.

NUM LOCK enables or disables the numeric buttons on the
Remote Controller.
FUNCTION LOCK enables or disables the SWITCH SITE,

VIDEO AUTO/MANUAL and ALM ACK buttons on the

Remote Controller. This setting is available only when the
unit is set to a receiver.

481 LOCK

MENU LOCK :

ON

OFF

NUM LOCK :

ON

OFF

FUNCTION LOCK:

ON

OFF

Tl:MOVE

SELECT ESC:PRV

1. Open the 481 LOCK menu.

2. Move the cursor to MENU LOCK and select either ON

or OFF with the or ► button. The default setting is

OFF.

ON: Password protection are enabled.
OFF: No password protection,

3. Move the cursor to NUM LOCK and select either ON or

OFF with the or ► button. The default setting is OFF,

ON: Numeric buttons are disabled.
OFF: Numeric buttons are operable.

45