Connections, Setup for peripheral devices, Address setup – Panasonic WV-CU20 User Manual
Page 127: Ps.data communication parameter setup, Input assignment, Setup for wj-nt204 transmitter
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/653950/127/background.png)
■ PS Data System Control (WJ-FS416, WJ-MP204s and WJ-HD100)
This is a system example empioying a WJ*FS416 (or FS409/FS316/FS309 instead), four WJ-MP204 and a WJ-HD100.
• Connections
1. Connect MULTISCREEN OUT on the rear of the WJ-FS416 to VIDEO IN on the WJ-NT204 with a BNC attached coaxial
cable.
2. Connect PLAY IN on the rear of the WJ-FS416 to SPOT OUT on the WJ-HD100 with a BNC attached coaxial cable,
3. Connect REG OUT on the rear of the WJ-FS416 to VIDEO IN on the WJ-HD100 with a BNC attached coaxial cable.
4. Connect 16 Combination cameras to CAMERA IN 1-4 on WJ-MP204 unit #1 through #4 with coaxial cables.
5. Connect CAMERA OUT 1-4 on WJ-MP204 unit #1 through #4 to VIDEO IN 1-16 on the WJ-FS416.
6. Connect DATA terminals among WJ-FS416, WJ-MP204 and WJ-HDIOO with RS-485 cables and branch connectors.
Combination Camara 1-16
CAMERA IN 1-4
WJ-MP204 I
M 3
CAMERA OUT 1-4
UÜ I
Note:
Set DIP switch #3 on the
rear of WJ-NT204 to ON,
VIDEO IN 1-16
WJ-F^16|r^|
RECOUT
VIDEO IN
PLAY IN
MONITOR
MULTI
OUT
OUT
WJ'HDIOO a *
VIDEO IN 1 '
WJ-NT204
m
• Setup for Peripheral Devices
1. Address Setup
Unit addresses must be set as follow.
Unit Name
WJ-FS416
WJ-HDIOO
WJ-MP204 #1
WJ-MP204 #2
WJ-MP204 #3
WJ-MP204 #4
Unit Address
1 (set in its own setup menu)
2 (set in its own setup menu)
3 (set with UNIT switch on its front panel)
4 (set with UNIT switch)
5 (set with UNIT switch)
6 (set with UNIT switch)
2. PS.Data Communication Parameter Setup
Every unit must be set to the same parameter in their own setup menus.
(For example, BAUD RATE: 9600 bps, DATA BIT: 8 bits. STOP BIT: 1 bit, PARITY: NONE)
3. Input Assignment
For WJ-FS-416, open COMMUNICATION SETUP menu, and set CAMERA NUMBER to 001 through 016.
For WJ-MP204 units, open CAMERA CONFIG menu on each unit, and set CAM NO. (camera numbers) as follows.
Unit Name
WJ-MP204 #1
WJ-MP204 #2
WJ-MP204 #3
WJ-MP204 #4
CAM NO.
1CH through 4CH
5CH through 8CH
9CH through 12CH
13CH through 16CH
For more information, refer to the manual included in each unit.
• Setup for WJ-NT204 Transmitter
1. On the ADMINISTRATOR SETUP PAGE, click the MODE SETUP button to open the MODE SETUP window.
2. Select either H.323/H.261 or JPEG in the MAIN PAGE DEFAULT MODE & INDEX FILE SELECT area.
Make the CONTROL SETUP as follows,
CAM CONTROL;
PS Data
AUX SYSTEM CONTROL: FS309/316/409/416
Default Unit Address:
1
Click SET & REBOOT. The WJ-NT204 transmitter will restart. Confirm the transmitter has restarted.
3. On the ADMINISTRATOR SETUP PAGE, click the SERIAL PORT button to open the SERIAL PORT SETUP window.
In the window, select PS.Data for TYPE, and set communication parameters the same as that other devices are set to.
127