beautypg.com

Panasonic WV-CU20 User Manual

Page 28

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Parallel In/Out Specifications

Pin#

Name

Specification/Note

1

GND

2

Clock Adjust In

Connect an Open Collector or non-voltage make-contact. Low Active (<0.2 V), Hold TimeilOO ms.
Controllable Capacity 5 V DC maximum

3

GND

Open Collector Output, Low Active, Hold Time»300 ms. Controllable Capacity 25 V DC 50 mA maximum

4

+ 12 V Out

DC source for relay driving, Current pin#4+#19i50 mA

5

Parallel Out 7

Open Collector Output, Low Active, Hold Time»300 ms. Controllable Capacity 25 V DC 50 mA maximum

6

Parallel Out 5

Same as Parallel Out 7

7

Parallel Out 4

Same as Parallel Out 7

8

Parallel Out 2

Same as Parallel Out 7

9

GND

10

Parallel In 7

Connect an Open Collector or non-voltage make-contact, Low Active {<0.2 V). Hold Time^lOO ms,
Controllable Capacity 5 V DC maximum

11

Parallel In 5

Same as Parallel In 7

12

Parallel In 3

Same as Parallel In 7

13

Parallel In 1

Same as Parallel In 7

14

Forced Disconnection
In

Communication Break /Specifications are same as other In terminals.

15

Mid-Communication

Out

Active (low) while the unit is in communication/Specifications are same as other Out terminals.

16

Strobe Out

A 300 ms negative pulse generated by any change of the parallel input to update 8 of parallel outputs /

Specifications are same as other Out terminals.

17

Parallel Out 8

Same as Parallel Out 7

18

Parallel Out 6

Same as Parallel Out 7

19

+ 12vOut

DC source for relay driving, Current pin#4+#19^50 mA

20

Parallel Out 3

Same as Parallel Out 7

21

Parallel Out 1

Same as Parallel Out 7

22

Parallel In 8

Same as Parallel In 7

23

Parallel In 6

Same as Parallel In 7

24

Parallel In 4

Same as Parallel In 7

25

Parallel In 2

Same as Parallel In 7

28