A D V A N C E D M A K E R U N F E A T U R E S
Run Options
Version 2
WinPEP 7 User Guide
6-5
Configuration Options—automatically takes care of setting different parameters to
speed up the configuration process.
• Apply Settings to Gauges — Several of the settings entered on the Run
Information screen are most likely intended to correspond with settings on
the gauges. For example, if the tachometer redline is 13,000 RPM, most users
would like the RPM gauges to display the same redline. If Apply Settings is
turned on, when the MakeRun Configuration dialog is closed, the settings
entered on the Run Information screen will be applied to the gauges.
• Default Run Name — The next run is automatically configured using the
newest run in the current run directory. However, if no runs are found in the
current run directory, the next run is configured using default information. In
this case, Default Run Name is the name given to the next run.
• Default Run Altitude — The next run altitude is automatically configured
using the current altitude in the directory. However, if no run altitude
information is found in the current run directory, the next altitude is
configured using default information.
• Default Redline — The next redline is automatically configured using the
current redline information in the directory. However, if no redline
information is found in the current run directory, the next redline is
configured using default information.
• Enable Differential Speed Warning — Warns when the dyno drums are
rotating at speeds that differ by more than the threshold value set for the
allowable speed differential.
• Speed Differential — Allows you to set the threshold value for the
Differential Speed Warning.
Control Run—turn off Load Control when run starts and automatically start sampling
and end sampling based on the current speed or engine speed.
• Turn Off Load Control When Run Starts—Select this option to automatically
turn off Load Control when the run starts. When this feature is off, Load
Control will remain on during the run and the Status Bar on the MakeRun
screen will flash “Sampling. . .” and “Load Control On” alternately.
• Automatically Start/Stop Run — Check or uncheck this option to turn
on or off. Outside the MakeRun Configuration dialog, you can also
use the Stoplight button on the toolbar
. Refer to “Using Auto Start/Stop”
on page 6-9 for more information.
• Available Channels — Select which channel (speed or engine speed) you
would like to use for Auto Start/Stop.
• Start/Stop Values — The values used by Auto Start/Stop to automatically start
and stop sampling.