Rockwell Automation FactoryTalk Report Expert User Guide User Manual
Page 57
Understanding Report Templates Chapter 5
Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014
57
The fields of the report template grid:
Item
Description
Uptime %
The percentage of available time that the machine was actually
running. The calculation for this field is:
Uptime % = RunningTime/AvailableTime.
Throughput %
The performance of a machine when it is running compared to its
ideal cycle time. The ideal cycle time depends upon the product
being produced and is measured in units of seconds per part. The
calculation for this field is:
Throughput = (TotalParts x IdealCycleTime) / Running Time.
Quality %
The percentage of total parts produced that were of good quality.
The calculation for this field is:
Quality % = GoodParts / Total Parts.
OEE %
The product of Uptime, Throughput, and Quality. The calculation for
this field is:
OEE % = Uptime x Throughput x Quality.
The values of the report template and other report templates to
which the values link using the drillthrough hierarchy:
Click a value in this column:
To display this report template:
Uptime %
Uptime
Throughput %
Throughput
Quality %
Quality
OEE %
Performance
The report template bar charts: OEE %.
The bar chart fields:
Item
Description
Value
OEE %
X axis grouping
First non-page grouping parameter
Series
Second non-page grouping