Chapter 8 Editing Event and Production Data
118
Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014
There are several restrictions related to editing the category and
name of events. You can change the category and name provided
that the event configuration fulfills the following conditions:
• It is user-defined.
• It is not active (i.e., it is not currently processed by the
FactoryTalk Metrics server).
• Its trigger type is one of the following:
• Monitored Bit Low to High.
• Monitored Bit High to Low.
• Monitored Formula Low to High.
• Monitored Formula High to Low.
• Monitored Expression Low to High.
• Monitored Expression High to Low.
• Manual active/inactive event.
To edit the category and name of an event:
1. Select the Edit Events operation and the desired parameter
set, and then click View Data.
TIP
Alternatively, select the Enter Data Manually operation and
the desired parameter set, and then click View Data. In the
Select Area and Shift Details panel, click Events.
The data is displayed in the Event list panel.
2. Under Actions, click Edit in the row with the event that you
want to edit.
The Category-Name field becomes editable.
3. In the Category - Name field, select the desired category and
name of the event.
Editing the Category - Name