4. Select the RptSetting table and open it for editing.
5. Under Value, modify the values of the settings as specified in
"Configuring Report Expert Settings (page 138)".
6. Restart the Internet Information Services (IIS):
1. In the Command Prompt window, type
iisreset
.
Wait until the services are restarted.
7. Restart SQL Server Reporting Services (SSRS):
1. Go to
Start > Run. The Run dialog box appears.
2. Type
services.msc. The Services dialog box appears.
3. Find the following service:
• SQL Server Reporting Services ( name>) 4. Right-click it, and then select Restart. Wait until the service is restarted. During the installation of Report Expert, communication between Report Expert and SQL Server Reporting Services (SSRS) is • Report Expert communicates with SSRS that are installed and configured on the same computer, on which you have installed • The URL of the Report Server Web Service is created. It consists of the following elements: / MSRSReportFolder> To change this configuration, use the settings described in the table Communicating With SQL
configured in the following way:
Report Expert.
http:/
below. The settings are stored in the RptSetting (page 138) table of
the FactoryTalk Metrics database.
Server Reporting Services
(SSRS)