20

.

33

Sh

ell

hou

si

ng

s

Electronic connectors in heavy duty housings

For applications where robust, high density, splash-proof connectors

are required, e.g. in the automated control and industrial processing

systems, HARTING have combined the proven reliability of DIN

41 612 connectors with standard Han

®

24 B heavy duty hoods

and housings, to bring forward a connector system with up to 96

ways and various contact plating thicknesses to suit the individual

requirements.

Advantages

The combination enhances design flexibility, as it permits an

identical wiring interface between the standard 19“ racking systems

and the peripheral equipment.

Simplified stock-holding, identical operating tools.

Inserts

Female

2 x 48 way type F female connectors with

crimp contact elements

see chapter 03

Male

2 x 48 way type F interface connectors I

with crimp contact elements

see chapter 03

Hoods and housings

see catalogue "Heavy Duty Han

®

Connectors"

chapter 30

size 24 B

Degree of protection for hoods and housings: IP 65

Retaining frames

For fixing the inserts into the housing.

Alternative versions with pre-mating contacts and ground termination.

If the working voltages are in excess of 42 V (50 V) it is essential to

use retaining frames which have pre-mating ground contacts.