Creepage and clearance distances, CTI
Extract DIN VDE 0110-04.97
*)
This standard is a technical adaptation of IEC Report 664/664A and
specifies, in general, the minimum insulation distances for equipment.
It can be used by committees to protect persons and property in the
best possible way from the effects of electrical voltages or currents
(e.g. fire hazard) or from functional failure of the equipment by pro-
viding adequate dimensioning of clearances and creepage distances
in equipment.
Rated impulse withstand voltage
In allocation of the equipment to an installation category, the following
factors shall be taken into account:
●
Overvoltages which can enter the equipment from outside across
the terminals.
●
Overvoltages generated in the equipment itself and occurring at the
terminals.
The following parameters apply to:
Installation category I
Equipment is intended for use only in appliances or installation parts,
in which no overvoltages can occur.
Equipment in this installation category in normally operated at
extra low voltage.
Installation category II
Equipment is intended for use in installations or parts of installations,
in which lightning overvoltages need not be considered. Overvoltages
caused by switching must be taken into account.
This includes for example domestic appliances.
Installation category III
Equipment is intended for use in installations or parts of installations,
in which lightning overvoltages need not be considered, but which are
subject to particular requirements with regard to the safety and availa-
bility of the equipment and its supply systems.
This includes equipment for fixed installation such as protective
devices, relays, switches and sockets.
Installation category IV
Equipment is intended for use in installations or parts of installations,
in which lightning overvoltages must be taken into account.
This includes equipment for connection to overhead lines such
as omnidirectional control receivers and meters.
For circuits or parts of circuits inside the equipment, clearances may
be dimensioned directly for the expected overvoltages. If the expected
overvoltages are not impulse voltages but DC or AC voltages, the
max imum value of these voltages shall be determined as the rated
im pulse withstand voltage for clearances both for homogeneous and
inhomogeneous field.
Degree of pollution
Pollution degree 1: No pollution or only dry, non-conductive pollution
occurs. The pollution has no influence.
Pollution degree 2: Only non-conductive pollution occurs. A temporary
conductive caused by condensation must be ex-
pected occasionally.
The degrees of pollution 3 and 4 are in this case not considered, as
they are not relevant for the connectors shown in this catalogue.
*)
It is the users responsibility to ensure that the complete current issue of the specification is considered.
Clearance
The clearance is defined as shortest distance through the air between
two conductive elements.
Clearance
To identify the clearance distance
●
Define the installation category
●
Define the degree of pollution expected
●
Select the rated impulse withstand voltage from table 00.01
●
Select the minimum required clearance from table 00.02
Exemplary calculation
What voltage can be used, if the clearance, the installation category
and the degree of pollution are known:
Creepage
The creepage is defined as shortest distance on the surface of an
insulating material between two conductive elements.
Creepage
To identify the creepage distance
●
Define the installation category
●
Define the degree of pollution expected
●
From the nominal voltage and the type of supply system select the
rated voltage from table 00.03 a/b
●
From the rated voltage and degree of pollution select the minimum
creepage and CTI group of the connector required in table 00.04
For the dimensioning of the creepage distance the tracking formation
of the insulating material has to be considered. If not indicated con-
trary, the CTI value of the insulating material is <400 and the isolation
group is III a/b.
Clearance
Installation
category
Degree
of pollution
Voltage
phase-to-earth
1.2 mm
II
2
150 V
3.0 mm
II
2
600 V
4.5 mm
II
2
600 V