Technical characteristics piggyback connectors – Northern Connectors Harting DIN 41 612 Connectors User Manual
Page 122
![background image](/manuals/569507/122/background.png)
03
.
22
DIN
P
ow
er
up t
o 6 A
Technical characteristics
piggyback connectors
Current carrying capacity
The current carrying capacity is limited by maximum temperature of
materials for inserts and contacts including terminals . The current
capacity curve is valid for continuous, non interrupted current loaded
contacts of connectors when simultaneous power on all contacts is
given, without exceeding the maximum temperature .
Control and test procedures according to DIN IEC 60 512
Piggyback connectors for interfacing with
female connectors with wrap posts 1 x 1 mm
The problem of interfacing systems designed for the distribution
or collection of electronic signals can be overcome by the use of
piggyback connectors . Designed to be mounted on the rear of
DIN 41 612 type wire wrap female connectors (1 x 1 mm posts)
these piggyback elements can be used to terminate input and
output cables .
Distance fixing brackets are fitted to provide either a latching or
screw fixing facility over the two level wire wrap plane .
The female crimp contacts used in these versions are designed
for 1 x 1 mm posts .
After crimping they can be easily inserted into the chambers of the
connector body with the aid of an insertion tool . Insertion errors
can be simply rectified with the use of a removal tool .
2 and 3 row piggyback connectors can be mounted in shell
housings C and open hood G . Security is provided by either
latches or screws to the distance fixing brackets .
Number of contacts
16, 32, 48
Working current
6 A max .
see current carrying capacity chart
Clearance
16 ways
≥ 1 .6 mm
32, 48 ways
≥ 1 .6 mm
Creepage
16 ways
≥ 1 .6 mm
32, 48 ways
≥ 3 .0 mm
Working voltage
The working voltage also depends
according to the safety
on the clearance and creepage regulations
of the equipment
dimensions of the pcb itself
Explanations see chapter 00
and the associated wiring
Contact resistance
≤ 20 mΩ
Insulation resistance
≥ 10
12
Ω for standard articles
Termination
Crimp terminal
0 .09-1 .5 mm²
Materials
Mouldings and hoods
Thermoplastic resin,
glass-fibre filled
Contacts
Copper alloy
W
or
king current
Ambient temperature
➀
with shell housing
➁
without shell housing