Functional test, Important notes – Lenze EVS9332xS User Manual
Page 354
Safety engineering
Functional test
Important notes
11.5
11.5.1
l
11.5−1
EDSVS9332S EN 6.0−07/2013
11.5
Functional test
11.5.1
Important notes
}
Danger!
Unexpected start−up of the machine possible
The "Safe torque off" safety function provides protection against
an unexpected start−up of the drive and therefore is an
important item within the safety concept for a machine. It has to
be ensured that this function works correctly.
Possible consequences:
ƒ
Death, severe injury, or damage to material assets, when the
safety function fails.
Protective measures:
After the installation and at regular intervals, the operator has to
check the function of the "Safe torque off" circuit.
ƒ
When doing this, check both disconnecting paths separately
with regard to their disconnection capability.
ƒ
The functional test can be carried out manually or
automatically via the PLC.
ƒ
Basically the inspection interval depends on the application
and the corresponding risk analysis, as well as on the system
as a whole. It should not exceed 1 year.
ƒ
If the functional test shows impermissible states,
– the drive or the machine has to be shut down immediately.
– commissioning is not permitted until the safety function
operates correctly.