Configuration, Code table – Lenze EVS9332xS User Manual
Page 285
Configuration
Code table
8.4
l
8.4−44
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1094 DENOMINATO
R
0.000
1
0.0001
{0.0001}
100000.0000 FEVAN1
Denominator
C1095 OFFSET
0
0
{1}
1000000000 FEVAN1
Offset setting
C1096
s
IN
1000 FIXED0%
® Selection list 1 FEVAN1
Configuration of analog input signal
C1097
s
FEVAN1−LOAD
1000 FIXED0
® Selection list 2 FEVAN1
Configuraton of digital input signal
C1098 (C1096)
g −32768
{1}
32767 FEVAN1
Display of analog input signal
C1099 (C1097)
g
FEVAN1
Display of digital input signal
C1100 FUNCTION
1
FCNT1
Function selection
1
Return
If |counter content|
³ |FCNT1−CMP−Val|,
FCNT1−EQUAL is set to HIGH for 1 ms
2
Hold if >=
If |counter content|
³ |FCNT1−CMP−Val|, the
counter stops
3
Hold if =
If |counter content| = |FCNT1−CMP−Val|, the
counter stops
C1101
s
® Selection list 1 FCNT1
Configuration − analog input signals
1 LD−VAL
1000 FIXED0%
2 CMP−VAL
1000 FIXED0%
C1102
s
® Selection list 2 FCNT1
Configuration of digital input signals
1 CLKUP
1000 FIXED0
2 CLKDWN
1000 FIXED0
3 LOAD
1000 FIXED0
C1103
g −32768
{1}
32768 FCNT1
Display of analog input signals
1 (C1101/1)
2 (C1101/2)
C1104
g
FCNT1
Display of digital input signals
1 (C1102/1)
2 (C1102/2)
3 (C1102/3)
C1120 SYNC MODE
2
0
1
2
Sync switched off
CAN sync activated
Terminal sync activated
SYNC1
Function
C1121
s
2
0
{1 ms}
13 SYNC1
The interpolation is restarted with every sync
signal.
1 SYNC CYCLE
2
SYNC1
Definition of the cycle time of the sync
signals (in the slave); only for system bus
2 INTERPOL. CYCL
2
SYNC1
Definition of the interpolation time between
the sync signals (in the slave), only for
terminal
C1122 SYNC TIME
0.460 0.000
{0.001
ms}
10.000 SYNC1
Phase shift between CAN sync and internal
control program cycle
l
For system bus only
l
Depends on baud rate and bus load