Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Display elements and function keys
7.2
7.2.3
l
7.2−4
EDSVS9332S EN 6.0−07/2013
4 Number
Active level
Meaning
Explanation
Menu level
Menu number
Display is only active for operation
with standard devices of the 8200
vector or 8200 motec series
Code level
Four−digit code number
5 Number
Active level
Meaning
Explanation
Menu level
Submenu number
Display is only active for operation
with standard devices of the 8200
vector or 8200 motec series
Code level
Two−digit subcode number
6 Parameter value
Parameter value with unit
7 Cursor
In the parameter level, the digit above the cursor can be directly changed
8 Function keys
For description see the following table
)
Note!
Shortcuts with
T:
Press and hold
T, then press the second key in addition.
Key
Function
Menu level
Code level
Parameter level
Operating level
V
Change to the
parameter level
Change to the
operating level
Change to the code
level
T V
Go to the
"Short setup"
menu and load
predefined
configurations
1)
Accept parameters
when SHPRG
p or
SHPRG is displayed
z
y
Change between
menu items
Change of code
number
Change of digit via
cursor
T z
T y
Quick change
between menu
items
Quick change of
code number
Quick change of
digit via cursor
Z
Change between main menu, submenu
and code level
Cursor to the right
Y
Cursor to the left
U
Deactivate the function of the key
S, the LED in the key goes off
S
Inhibit the controller, the LED in the key is lit.
Reset fault
(TRIP−Reset):
1. Remove the cause of malfunction
2. Press
S
3. Press
U
1)
Only active for operation with standard devices of the 8200 vector or 8200 motec series
Function keys