Free configuration of digital input signals, Commissioning, Danger – Lenze EVS9332xS User Manual
Page 202
Commissioning
Changing the assignment of the control terminals X5 and X6
Free configuration of digital input signals
6.9
6.9.1
l
6.9−1
EDSVS9332S EN 6.0−07/2013
6.9
Changing the assignment of the control terminals X5 and X6
}
Danger!
If you select a configuration in C0005, the signal assignment of
the inputs and outputs will be overwritten with the
corresponding basic assignment!
ƒ
Adapt the signal assignment to your wiring!
6.9.1
Free configuration of digital input signals
ƒ Internal digital signals can be freely linked with external digital signal
sources. This serves to establish a freely configurable control of the
drive controller.
– Digital inputs X5/E1 ... X5/E5
ƒ A signal source can be linked with several targets. Ensure reasonable
linkages for not activating functions that are mutually exclusive (e. g.
linking a digital input with quick stop and DC injection braking at the
same time).
The internal digital signal can be linked with an external signal source by
entering the selection figure of the external signal into the configuration
code of the internal digital signal.
Example
ƒ C0787/2 =53
ð signal source for JOG2 is terminal X5/E3
E1
E2
E3
E4
E5
1
0
C0114/1...6
DIGIN
DIGIN1
DIGIN2
DIGIN3
DIGIN4
DIGIN5
28
DCTRL -X5/28
X5
DIGIN-CINH
1
1
ST
DIGIN6
C0443
NSET
C0046
NSET-N
DMUX
0
3
0
15
NSET-JOG*1
NSET-JOG *2
NSET-JOG *4
NSET-JOG *8
JOG1...15
C0780
C0787/1
C0787/2
C0787/3
C0787/4
9300vec105
Fig. 6.9−1
Connecting digital signal JOG2 with terminal X5/E3
I
Tip!
ƒ
A list with all selection figures is included in the chapter
"Configuration"
® "Selection lists".
ƒ
For signal linkage we recommend the function block editor in
GDC (ESP−GDC2).
Description
Linking signals