Configuration, Code table – Lenze EVS9332xS User Manual
Page 263
Configuration
Code table
8.4
l
8.4−22
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0528
g −2
.
10
9
{1}
2
.
10
9
DFSET
1 0−PULSE A
Angular difference between 2 zero pulses
2 OFFSET
Offset results from C0523 × C0529 + C0252
3 PULSE DIST SET
Number of increments between two set
pulses at X5/E5.
Code is available from software version 6.2.
4 PULSE DIST ACT
Number of increments between two actual
pulses at X5/E4.
Code is available from software version 6.2.
C0529 MULTIP OFFSET
1
−20000
{1}
20000 Offset multiplier
C0530 DF
EVALUATION
0
0
With gearbox factor
DFSET
Evaluation of the digital frequency
1
Without gearbox factor
C0531 ACT 0 DIV
1
1
{1}
16384 DFSET actual zero pulse scaler
C0532 0−PULSE/TP
1
1
2
3
0−pulse
Touch probe
0 pulse and touch probe
DFSET zero pulse/touch probe
Selection of zero pulse, touch probe, or zero
pulse and touch probe
C0533 VP DENOM
1
1
{1}
32767 DFSET Vp denominator
Gain factor denominator
C0534 SYNC MODE
0
0
1
2
10
11
12
13
Inactive
Continuous
Continuously switchable
Once, fast way
Once, + direction
Once, − direction
Once, 2 × zero pulse
DFSET
Mode for synchronising the zero pulse and/or
touch probe
C0535 SET 0 DIV
1
1
{1}
16384 DFSET
Setpoint zero pulse divider
C0536
g −32767
{1}
32767 DFSET
Display of analog input signals
1 (C0521)
2 (C0522)
3 (C0523)
C0537 (C0524)
g −199.99
{0.01 %}
199.99 DFSET
Display of analog input signal
C0538
g
DFSET
Display of digital input signals
1 (C0525)
2 (C0526)
3 (C0527)
C0539 (C0520)
g −32767
{1 rpm}
32767 DFSET
Input signal display
C0540 FUNCTION
2
0
1
2
3
4
5
Analog input
Phase difference input
Resolver simulation + zero pulse
Resolver simulation without zero pulse
X10 = X9
X10 = X8
DFOUT
Function of the encoder outputs
C0541
s
AN−IN
5001 MCTRL−NACT
® Selection list 1 DFOUT
Configuration of analog input
C0542
s
DF−IN
1000 FIXEDPHI−0
® Selection list 4 DFOUT
Configuration of the dig. frequency input
C0544
s
SYN−RDY
1000 FIXED0
® Selection list 2 DFOUT
Synchronisation signal for the zero pulse
C0545 PH OFFSET
0
0
{1 inc}
65535 DFOUT
Angular offset