Display elements and function keys, Parameter setting – Lenze EVS9332xS User Manual
Page 212

Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Display elements and function keys
7.2
7.2.3
l
7.2−3
EDSVS9332S EN 6.0−07/2013
7.2.3
Display elements and function keys
Y Z
y
z
T V
S U
d
A
B
b
c
p
SHPRG
Para
Code
Menu
0050
00
50.00_Hz
M C T R L - N O U T
0
1
3
4
5
6
7
8
2
9371BC002
Fig. 7.2−2
Display elements and function keys of the XT EMZ9371BC keypad
0 Status displays of standard device
Display
Meaning
Explanation
d
Ready for operation
c
Pulse inhibit is active
Power outputs are inhibited
b
The set current limit is exceeded in
motor or generator mode
B
Speed controller 1 in the limitation
Drive is torque−controlled
(Only active for operation with
standard devices of the 9300
series)
A
Active fault
1 Acceptance of the parameters
Display
Meaning
Explanation
p
Parameter is accepted immediately
Standard device operates
immediately with the new
parameter value
SHPRG
p
Parameter must be acknowledged
with
T V
Standard device operates with the
new parameter value after being
acknowledged
SHPRG
Parameter must be acknowledged in
case of controller inhibit
T V
Standard device operates with the
new parameter value after the
controller is enabled again
None
Display parameter
Change is not possible
2 Active level
Display
Meaning
Explanation
Menu
Menu level is active
Select main menu and submenus
Code
Code level is active
Select codes and subcodes
Para
Parameter level is active
Change parameters in the codes or
subcodes
None
Operating level is active
Display operating parameters
3 Short text
Display
Meaning
Explanation
alphanumeric
al
Contents of the menus, meaning of
the codes and parameters
In the operating level display of
C0004 in % and the active fault
Displays