Configuration, Code table – Lenze EVS9332xS User Manual
Page 260
Configuration
Code table
8.4
l
8.4−19
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0465
s
FB LIST
®
® Selection list 5 FB processing list
Includes the program for signal processing
(sequence in which the function blocks are
processed)
à
Depending on C0005. Change of C0005
loads assigned processing list
à
Valid for C0005 = 1000
l
After changing the signal flow the
processing list must be adapted.
Otherwise the device may work with
wrong signals!
l
The function blocks DIGIN, DIGOUT,
AIF−IN, CAN−IN, and MCTRL are always
processed and do not have to be entered
in the list.
1
200
2
0
3
50
4
0
5
0
6
55
7
0
8
0
9
10250
10
0
11
0
12
0
13
5650
14
0
15
0
16
5050
...
0
19
5700
...
0
22
10650
...
0
25
70
..
0
28
75
...
0
31
250
...
0
41
25000
42
20000
...
0
49
0
50
0
C0466 CPU T REMAIN
g
Remaining process time
For processing function blocks
C0469
s
KEY
STOPFUNCTIO
N
2
0
1
2
switched off
set controller inhibit
set quick stop
set function of the STOP key on the keypad
C0470
0
{1}
255 Freely configurable code for digital signals
l
Data words C0470 and C0471 are in
parallel and identical
0 FCODE 8BIT
DIGITAL
0
1 FCODE BIT 0−7
0
2 FCODE BIT8−15
0
3 FCODE
BIT16−23
0
4 FCODE
BIT24−31
0