Configuration, Code table – Lenze EVS9332xS User Manual
Page 271

Configuration
Code table
8.4
l
8.4−30
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0741
OSZ
1 VERSION OSZ
g
Version
2 LENGTH
MEMORY
Memory size
3 DATA WIDTH
Data width
4 NO. CHANNELS
Number of channels
C0742 LENGTH OF DB
g
OSZ
Show data block length
C0743 READ DB
g
OSZ
Reading an 8 byte data block
C0744 MEM: DEPTH
2048 0
1
2
3
4
5
6
512 measured values
1024 measured values
1536 measured values
2048 measured values
3072 measured values
4096 measured values
8192 measured values
OSZ
Adapt memory depth to the measuring task
C0749
g
OSZ
Information on the storage of the measured
values
1 BRK:OFF INDEX
2 TRIGGER INDEX
3 END INDEX
C0750 VP DENOM
16
1
2
4
8
16
34
64
128
256
512
1024
2048
4096
8192
16384
Vp = 1
Vp = 1/2
Vp = 1/4
Vp = 1/8
Vp = 1/16
Vp = 1/32
Vp = 1/64
Vp = 1/128
Vp = 1/256
Vp = 1/512
Vp = 1/1024
Vp = 1/2048
Vp = 1/4096
Vp = 1/8192
Vp = 1/16384
DFRFG1
Denominator of the position controller gain
C0751 DFRFG1 TIR
1.000 0.001
{0.001 s}
999.900 DFRFG1
T
ir
(acceleration time)
C0752 MAX SPEED
3000 1
{1 rpm}
16000 DFRFG1
Maximum speed (here: maximum
compensation speed)
C0753 DFRFG1 QSP
0.000 0.000
{0.001 s}
999.900 DFRFG1
Deceleration time T
if
for activation of the
deceleration ramp
C0754 PH ERROR
2
.
10
9
10
{1 inc}
2
.
10
9
DFRFG1
Following error
C0755 SYN WINDOW
100
0
{1 inc}
65535 DFRFG1
Synchronisation window
C0756 OFFSET
0
−1
.
10
9
{1 inc}
1
.
10
9
DFRFG1
Offset
C0757 FUNCTION
0
0
1
TP start inactive
TP start active
DFRFG1
Function
C0758
s
IN
1000 FIXEDPHI−0
® Selection list 4 DFRFG1
Input signal configuration
C0759
s
QSP
1000 FIXED0
® Selection list 2 DFRFG1
Configuraton of digital input signal