Configuration, Code table – Lenze EVS9332xS User Manual
Page 269
Configuration
Code table
8.4
l
8.4−28
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0697
s
® Selection list 3 PHCMP1
Input signal configuration
1 IN
1000 FIXED0INC
2 IN
1000 FIXED0INC
C0698
g −2147483647
{1}
2147483647 PHCMP1
Display of input signals
1 (C0697/1)
2 (C0697/2)
C0700
s
IN
19523 FCODE−472/3
® Selection list 1 ANEG1
Configuration of analog input signal
C0701 (C0700)
g −199.99
{0.01 %}
199.99
C0703
s
IN
1000 FIXED0%
® Selection list 1 ANEG2
Configuration of analog input signal
C0704 (C0703)
g −199.99
{0.01 %}
199.99
C0710 FUNCTION
0
0
1
2
Rising edge
Falling edge
Both edges
TRANS1
Signal evaluation
In the case of a corresponding signal edge at
IN, OUT switches to HIGH
C0711 PULSE T
0.001 0.001
{0.001 s}
60.000 TRANS1
Pulse time of TRANS1
C0713
s
IN
1000 FIXED0
® Selection list 2 TRANS1−IN
Configuraton of digital input signal
C0714 (C0713)
g
TRANS1−IN
Display of digital input signal
C0715 FUNCTION
0
0
1
2
Rising edge
Falling edge
Both edges
TRANS2
Signal evaluation
In the case of a corresponding signal edge at
IN, OUT switches to HIGH
C0716 PULSE T
0.001 0.001
{0.001 s}
60.000 TRANS2
Pulse duration
C0718
s
IN
1000 FIXED0
® Selection list 2 TRANS2
Configuraton of digital input signal
C0719 (C0718)
g
TRANS2
Display of digital input signal
C0720 FUNCTION
2
0
1
2
On delay
Off delay
On/off delay
DIGDEL1
Function selection
C0721 DELAY T
1.000 0.001
{0.001 s}
60.000 DIGDEL1
Setting of the delay time
C0723
s
IN
1000 FIXED0
® Selection list 2 DIGDEL1
Configuraton of digital input signal
C0724 (C0723)
g
DIGDEL1
Display of digital input signal
C0725 FUNCTION
2
0
1
2
On delay
Off delay
On/off delay
DIGDEL2
Function selection
C0726 DELAY T
1.000 0.001
{0.001 s}
60.000 DIGDEL2
Setting of the delay time
C0728
s
IN
1000 FIXED0
® Selection list 2 DIGDEL2
Configuraton of digital input signal
C0729 (C0728)
g
DIGDEL2
Display of digital input signal
C0730 OSZ MODUS
0
0
1
Start measurement
Stop measurement
OSZ
Start / stop of the measured value recording