Configuration, Code table – Lenze EVS9332xS User Manual
Page 264

Configuration
Code table
8.4
l
8.4−23
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0546 PULSE MIN SET
1000 1
{1 inc}
2147483647 DFSET
Masking (suppressing) interference pulses at
X5/E5 (set pulse of touch probe signal).
The size of the masking window between
two set pulses is set.
C0547 (C0541)
g −199.99
{0.01 %}
199.99 DFOUT
Display of analog input signal
C0548 (C0544)
g 0
1 DFOUT
Display of digital input signal
C0549 (C0542)
g −32767
{1 rpm}
32767 DFOUT
Input signal display
C0551 PULSE MIN ACT
1000 1
{1 inc}
2147483647 DFSET
Masking (suppressing) interference pulses at
X5/E4 (actual pulse of touch probe signal).
The size of the masking window between
two actual pulses is set.
Code is available from software version 6.2.
C0560 FIX SET−VALUE
−199.99
{0.01 %}
199.99 Fixed setpoints
1
100
2
75
3
50
4
25
5
0
...
...
15
0
C0561
s
AIN
1000 FIXED0%
® Selection list 1 FIXSET1
Configuration of analog input signal
C0562
s
® Selection list 2 FIXSET1
Configuration of digital input signals
1 IN1
1000 FIXED0
2 IN2
1000 FIXED0
3 IN3
1000 FIXED0
4 IN4
1000 FIXED0
C0563 (C0561)
g −199.99
{0.01 %}
199.99 FIXSET1
Display of analog input signal
C0564
g
FIXSET1
Display of digital input signals
1 (C0562/1)
... ...
4 (C0562/4)
C0570
s
IN
1000 FIXED0%
® Selection list 1 S&H1
Configuration of analog input signal
C0571
s
LOAD
1000 FIXED0
® Selection list 2 S&H1 LOAD
Configuraton of digital input signal
C0572 (C0570)
g −199.99
{0.01 %}
199.99 S&H1
Display of analog input signal
C0573 (C0571)
g
S&H1 LOAD
Display of digital input signal
C0575 SD8 FILTER
1
0
{1 ms}
200 SD8 monitoring
Tripping delay of error message SD8
C0576
100.0
0
0.00
{0.01 %}
100.00 nErr monitoringspeed window
Setting of the system deviation between
actual speed value and speed setpoint
C0577 VP FLD WEAK
3.00
0.00
{0.01}
15.99 Field weakening controller
V
pgain