Configuration – Lenze EVS9332xS User Manual
Page 272
Configuration
Code table
8.4
l
8.4−31
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0760
s
STOP
1000 FIXED0
® Selection list 2 DFRFG1−STOP
Configuraton of digital input signal
"Ramp function generator stop"
C0761
s
RESET
1000 FIXED0
® Selection list 2 DFRFG1
Configuraton of digital input signal
Reset integrators
C0764
g
DFRFG1
Display of digital input signals
1 (C0759)
2 (C0760)
3 (C0761)
C0765 (C0758)
g −32767
{1 rpm}
32767 DFRFG1
Input signal display
C0766 SPEED DIR
1
1
2
3
both directions (cw/ccw)
positive direction only (cw)
negative direction only (ccw)
DFRFG1
Define direction of rotation
C0770
s
D
1000 FIXED0
® Selection list 2 FLIP1
Data input
Configuraton of digital input signal
C0771
s
CLK
1000 FIXED0
® Selection list 2 FLIP1
Configuration of clock input signal
C0772
s
CLR
1000 FIXED0
® Selection list 2 FLIP1
Configuration of reset input signal
C0773
g
FLIP1
Display of digital input signals
1 (C0770)
2 (C0771)
3 (C0772)
C0775
s
D
1000 FIXED0
® Selection list 2 FLIP2
Data input
Configuraton of digital input signal
C0776
s
CLK
1000 FIXED0
® Selection list 2 FLIP2
Configuration of clock input signal
C0777
s
CLR
1000 FIXED0
® Selection list 2 FLIP2
Configuration of reset input signal
C0778
g
FLIP1
Display of digital input signals
1 (C0775)
2 (C0776)
3 (C0777)
C0780
s
N
50
AIN1−OUT
® Selection list 1 NSET
Configuration of input signal for main
setpoint
C0781
s
N−INV
10251 R/L/Q−R/L
® Selection list 2 NSET
Configuration of input signal for main
setpoint inversion
C0782
s
NADD
5650 ASW1−OUT
® Selection list 1 NSET
Configuration of input signal for additional
setpoint
C0783
s
NADD−INV
1000 FIXED0
® Selection list 2 NSET
Configuration of inversion of additional
setpoint
C0784
s
CINH−VAL
5001 MCTRL−NACT
® Selection list 1 NSET
Configuration of output signal with inhibited
controller