Configuration, Code table – Lenze EVS9332xS User Manual
Page 281

Configuration
Code table
8.4
l
8.4−40
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0924
s
REF−POS−LOAD
1000 FIXED0
® Selection list 2 REF
Configuraton of digital input signal
Control "set position"
C0925
s
REF−ACTPOS−IN
1000 FIXED0INC
® Selection list 3 REF
Configuration of input signal for "Set
position"
C0926
g −2147483647
{1 inc}
2147483647 REF
1 REF−ACTPOS−IN
Display of input signals
2 REF−PHI−IN
3 REF−ACTPOS
Actual position
4 REF−TARGET
Target position
C0927
g
REF
Display of digital input signals
1 REF−ON
2 REF−MARK
3 REF−POS−LOAD
C0928 REF−PHI−IN
g −2147483647
{1 inc}
2147483647 REF
Angle signal (following error)
l
1 rev. = 65536 inc
C0929 REF−N−IN
g −199.99
{0.01 %}
199.99 REF
Display of analog input signal
C0930
s
REF−GEARBOX
MOT
1
1
{1}
65535 REF
Encoder/gearbox factor − numerator (on the
motor side)
C0931
s
REF−GEARBOX
ENC
1
1
{1}
65535 REF
Encoder/gearbox factor − denominator (on
the encoder side)
C0932 REF MODE
0
REF
Homing function mode
0
Mode 0
Positive direction, reference switch, zero
pulse
1
Mode 1
Negative direction, reference switch, zero
pulse
6
Mode 6
Positive direction, reference switch, touch
probe
7
Mode 7
Negative direction, reference switch, touch
probe
8
Mode 8
Positive direction, touch probe
9
Mode 9
Negative direction, touch probe
20
Mode 20
Direct homing
21
Mode 21
Direct homing, save actual value
C0933 REF TRANS
0
0
1
Rising edge
Falling edge
REF
Reference signal edge
C0934 REF OFFSET
0
−2140000000
{1 inc}
2140000000 REF
Home position offset
C0935 REF SPEED
2.000
0
0.0001
{0.0001
%}
100.0000 REF
Homing speed
Homing speed
The value set is the percentage value of N
max
C0936 REF TI
1.00
0.01
{0.01 s}
990.00 REF
Homing acceleration/deceleration time
T
ir
and T
if
are identical
C0940 NUMERATOR
1
−32767
{1}
32767 CONV1
Numerator