Configuration
Code table
8.4
l
8.4−29
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0731 OSZ STATUS
0
0
1
2
3
4
5
Measurement completed
Measurement active
Trigger detected
Abort
Abort after trigger
Read memory
OSZ
Current operating status
C0732
s
® Selection list 1 OSZ
Configuration − analog input signals
1 CHANNEL1
1000 FIXED0%
2 CHANNEL2
1000 FIXED0%
3 CHANNEL3
1000 FIXED0%
4 CHANNEL4
1000 FIXED0%
C0733
® Selection list 2 OSZ
Trigger input
1 TRIG INP
1000 FIXED0
C0734 TRIG−SOURCE
1
0
1
2
3
4
Digital trigger input
Measuring channel 1
Measuring channel 2
Measuring channel 3
Measuring channel 4
OSZ
Selection of trigger source
C0735 TRIGGER−LEVEL
0
−32767
{1}
32767 OSZ
Set trigger level for channels 1 ... 4
C0736 TRIGGER−SLOPE
0
0
1
LOW−HIGH edge
HIGH−LOW edge
OSZ
Selection of the trigger edge
C0737 TRIGGER DELAY
0.0
−100.0
{0.1 %}
999.9 OSZ
Setting of pretriggering and posttriggering
C0738 PROBE PERIOD
3
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
1 s
2 s
5 s
10 s
20 s
50 s
1 min
2 min
5 min
10 min
OSZ
Selection of the sampling period
C0739 NUMBER OF
CHANNELS
4
1
{1}
4 OSZ
Number of channels to be measured
C0740 DATA READ
0
OSZ
1
0
0
{1}
65535 Define the starting point for reading the data
memory. This enables a selective access to a
memory block
2
0
0
1
Inhibit "Read data"
Enable "Read data"
Inhibit "Read memory"