Configuration, Code table – Lenze EVS9332xS User Manual
Page 248
Configuration
Code table
8.4
l
8.4−7
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0094 PASSWORD
0
0
{1}
9999 Password
l
Parameter access protection for the
keypad. When the password is activated,
only codes of the user menu can be
accessed. For further possible selections
see C0096
C0095
s
ROTOR POS
ADJ
0
0
1
Inactive
Active
Rotor position adjustment of a synchronous
motor
l
C0058 displays the zero angle of the rotor
l
C0095 = 1 starts position adjustment
C0096
s
0
1
2
3
No access protection
Read protection
Write protection
Read/write protection
Extended password protection for bus
systems with activated password (C0094).
l
All codes in the user menu can be
accessed.
1 AIF PROTECT.
0
AIF access protection
2 CAN PROTECT.
0
CAN access protection
C0099 S/W VERSION
g x.xx
Software version
C0101
0.000
{0.001 s}
999.900 NSET
Additional acceleration for the main setpoint
(based on speed variation 0...n
max.
)
1 NSET−TIR
(ACCELERATIO
N)
0.000
2 NSET TIR
0.000
... ...
...
15 NSET−TIR
0.000
C0103
0.000
{0.001 s}
999.900 NSET
Additional deceleration times for the main
setpoint
(based on speed variation 0...n
max.
)
1 NSET−TIF
0.000
2 NSET−TIF
0.000
... ...
...
15 NSET−TIF
0.000
C0105 QSP TIF
0.000 0.000
{0.001 s}
999.900 QSP deceleration time
Deceleration time for quick stop (QSP)
(based on speed variation 0...n
max.)
C0108
100.0
0
−199.99
{0.01 %}
199.99 FCODE (AOUT gain)
1 FCODE (GAIN
AOUT)
2 FCODE (GAIN
AOUT)
C0109
−199.99
{0.01 %}
199.99 FCODE (offset AOUT)
1 FCODE (OFFSET
AOUT)
0.00
2 FCODE (OFFSET
AOUT)
0.00
C0114
0
1
HIGH active
LOW active
DIGINterminal polarity
1 DIGIN1 POL
0
X5/E1
2 DIGIN2 POL
0
X5/E2
3 DIGIN3 POL
0
X5/E3
4 DIGIN4 POL
1
X5/E4
5 DIGIN5 POL
0
X5/E5