Table of attributes, Configuration – Lenze EVS9332xS User Manual
Page 302
Configuration
Table of attributes
8.6
l
8.6−1
EDSVS9332S EN 6.0−07/2013
8.6
Table of attributes
The attribute table describes the properties of the codes used. It enables you
to create your own communication programs for the controller.
How to read the table of attributes
Column
Abbreviation
Meaning
Code
Cxxxx
Name of the Lenze code
Index
dec
24575 − Lenze code
number
Index under which the
parameter is addressed
The subindex of array variables
corresponds to the Lenze
subcode number
Is only required for control via INTERBUS,
PROFIBUS DP or system bus (CAN)
hex
5FFFh − Lenze code
number
Data
DS
E
Data structure
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
xx
Number of array elements
(subcodes)
DT
B8
Data type
1 byte bit−coded
B16
2 bytes bit−coded
B32
4 bytes bit−coded
FIX32
32−bit value with sign;
decimal with four decimal places
I32
4 bytes with sign
U32
4 bytes without sign
VS
ASCII string
Format
VD
LECOM format
(see also Operating Instructions
of the bus module)
ASCII decimal format
VH
ASCII hexadecimal format
VS
String format
VO
Octet string format for data blocks
DL
Data length in byte
The column "Important" contains further
information
Access
LCM−R/W Ra
Access authorisation for LECOM
Reading is always permitted
Wa
Writing is always permitted
W
Writing is restricted
Condition CINH
Condition for writing
Writing permitted only when controller is
inhibited