Configuration, Code table – Lenze EVS9332xS User Manual
Page 283

Configuration
Code table
8.4
l
8.4−42
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0972
s
RESET
1000 FIXED0
® Selection list 2 MFAIL
Configuration of digital input signal (reset of
the mains failure control)
C0973
s
ADAPT
1000 FIXED0%
® Selection list 1 MFAIL
Configuration of input signal for adaptation
of the voltage controllerP gain
C0974
s
CONST
1000 FIXED0%
® Selection list 1 MFAIL
Configuration of input signal for adaptation
of the voltage controllerP gain
C0975
s
THRESHLD
1000 FIXED0%
® Selection list 1 MFAIL
Configuration of input signal for restart
protection for when speed threshold is
under−run
C0976
s
NACT
1000 FIXED0%
® Selection list 1 MFAIL
Configuration of input signal for comparison
value for threshold function
l
Start for V
2
controller
C0977
s
SET
1000 FIXED0%
® Selection list 1 MFAIL
Configuration of input signal for speed
starting value
C0978
s
DC−SET
1000 FIXED0%
® Selection list 1 MFAIL
Configuration of input signal for DC−bus
voltage setpoint
C0980 MFAIL VP
0.500 0.001
{0.001}
31.000 MFAIL
Setting of gain V
p
C0981 MFAIL TN
100
20
{1 ms}
2000 MFAIL
Setting of reset time T
n
C0982 MFAIL TIR
2.000 0.001
{0.001 s}
16.000 MFAIL
Setting of acceleration time T
ir
C0983 RETRIGGER T
1.000 0.001
{0.001 s}
60.000 MFAIL
Retrigger time
C0988
g −199.99
{0.01 %}
199.99 MFAIL
Display of analog input signals
1 (C0970)
2 (C0973)
3 (C0974)
4 (C0975)
5 (C0976)
6 (C0977)
7 (C0978)
C0989
g
MFAIL
Display of digital input signals
1 (C0971)
2 (C0972)
C0990
s
IN
1000 FIXEDPHI−0
® Selection list 4 PHINT1
Input signal configuration
C0991
s
RESET
1000 FIXED0
® Selection list 2 PHINT1
Configuration − reset signal
C0992 (C0990)
g −32767
{1}
32767 PHINT1
Input signal display
C0993 (C0991)
g
PHINT1
Display of digital input signal
C0995 DIVISION
0
−31
{1}
31 PHDIV
Divisor in the power−of−two−format (2
C0995
)
C0996
s
IN
1000 FIXED0INC
® Selection list 3 PHDIV
Input signal configuration