Configuration – Lenze EVS9332xS User Manual
Page 265
Configuration
Code table
8.4
l
8.4−24
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0578 TN FLD WEAK
50.0
2.0
{0.5 ms}
8192.0 Field weakening controller
Reset time Tn
C0578 = 8000 ms: Switched off
C0579 MONIT NERR
3
0
1
2
3
Trip
Message
Warning
Off
NEERmonitoring
Configuration of "system deviation between
actual speed value and speed setpoint"
monitoring
C0580 MONIT SD8
3
0
3
Trip
Off
SD8 monitoring
Configuration of "Encoder error at X8"
monitoring
C0581 MONIT EER
0
0
1
2
3
Trip
Message
Warning
Off
EEr monitoring
Configuration of "external fault" monitoring
C0582 MONIT OH4
2
2
3
Warning
Off
OH4monitoring
Configuration of heatsink temperature
monitoring
C0583 MONIT OH3
®
0
2
3
Trip
Warning
Off
OH3 monitoring
Configuration of "fixed motor temperature"
monitoring
à
Depending on C0086
C0584 MONIT OH7
®
2
3
Warning
Off
OH7monitoring
Configuration of "adjustable motor
temperature"monitoring
à
Depending on C0086
Temperature monitoring via resolver input
C0585 MONIT OH8
3
0
2
3
Trip
Warning
Off
OH8 monitoring
Configuration of "adjustable motor
temperature" monitoring
Temperature monitoring via PTC input
C0586 MONIT SD2
0
0
2
3
Trip
Warning
Off
SD2 monitoring
Configuration of resolver monitoring
C0587 MONIT SD3
3
0
2
3
Trip
Warning
Off
SD3 monitoring
Configuration of "encoder at X9" monitoring
C0588 MONIT
H10/H11
0
0
Trip
H10 / H11 monitoring
2
3
Warning
Off
Setting C0588 = 2 or C0588 = 3 only allowed
for Lenze service
C0589 MONIT P03
2
0
2
3
Trip
Warning
Off
P03monitoring
Configuration of following error monitoring
l
The following error is monitored by the
DFSET function block. The monitoring is
only active if DFSET is used.
C0590 MONIT P13
0
0
2
3
Trip
Warning
Off
P13 monitoring
Configuration of angle error monitoring
l
The following error is monitored by the
DFSET function block. The monitoring is
only active if DFSET is used.
C0591 MONIT CE1
3
0
2
3
Trip
Warning
Off
CE1 monitoring
Configuration of "CAN−IN1 fault" monitoring
C0592 MONIT CE2
3
0
2
3
Trip
Warning
Off
CE2monitoring
Configuration of "CAN−IN2 error" monitoring
C0593 MONIT CE3
3
0
2
3
Trip
Warning
Off
CE3 monitoring
Configuration of "CAN−IN3 error" monitoring