Code table
8.4
l
8.4−33
EDSVS9332S EN 6.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0805
s
I−OFF
1000 FIXED0
® Selection list 2 PCTRL1
Configuration of digital input signal
(switch−off I component)
C0808
g −199.99
{0.01 %}
199.99 PCTRL1
Display of analog input signals
1 (C0800)
2 (C0801)
3 (C0802)
4 (C0803)
C0809
g
PCTRL1
Display of digital input signals
1 (C0804)
2 (C0805)
C0810
s
® Selection list 1 ASW1
Configuration − analog input signals
1 IN
55
AIN2−OUT
2 IN
1000 FIXED0%
C0811
s
SET
1000 FIXED0
® Selection list 2 ASW1
Configuraton of digital input signal
C0812
g −199.99
{0.01 %}
199.99 ASW1
Display of analog input signals
1 (C0810/1)
2 (C0810/2)
C0813 (C0811)
g
ASW1
Display of digital input signal
C0815
s
® Selection list 1 ASW2
Configuration − analog input signals
1 IN
1000 FIXED0%
2 IN
1000 FIXED0%
C0816
s
SET
1000 FIXED0
® Selection list 2 ASW2
Configuraton of digital input signal
C0817
g −199.99
{0.01%}
199.99 ASW2
Display of analog input signals
1 (C0815/1)
2 (C0815/2)
C0818 (C0816)
g
ASW2
Display of digital input signal
C0820
s
® Selection list 2 AND1
Configuration of digital input signals
1 IN
1000 FIXED0
2 IN
1000 FIXED0
3 IN
1000 FIXED0
C0821
g
AND1
Display of digital input signals
1 (C0820/1)
2 (C0820/2)
3 (C0820/3)
C0822
s
1000
® Selection list 2 AND2
Configuration of digital inputs
1 IN
1000 FIXED0
2 IN
1000 FIXED0
3 IN
1000 FIXED0