4. Commissioning

4−19

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

4.5.2

Controlling the CMAX in record select operating mode

I/O data: Record select mode

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

O data

CCON

CPOS

Record no. Reserved

Reserved

I data

SCON

SPOS

Record no. RSB

Primary actual value (actual position, actual
force)

Allocation of the control bytes (overview)

CCON
Byte 1

B7
OPM2

B6
OPM1

B5
LOCK

B4
ć

B3
RESET

B2
BRAKE

B1
STOP

B0
ENABLE

y

To select the operatĆ
ing mode, see
Tab. 4/3

Software
access
blocked

ć

Acknow−
ledge malĆ
function

Release
brake

Stop

Enable
drive

CPOS
Byte 2

B7
ć

B6
CLEAR

B5
TEACH

B4
JOGN

B3
JOGP

B2
HOM

B1
START

B0
HOLD

y

ć

ć

Teach
value

Jog,
negative

Jog, posiĆ
tive

Start
homing

Start
positionĆ
ing job

ć

Record no. Byte 3: Record number of the record to be started.

Allocation of the status bytes (overview)

SCON
Byte 1

B7
OPM2

B6
OPM1

B5
FCT_MMI

B4
24VL

B3
FAULT

B2
WARN

B1
OPEN

B0
ENABLED

Byte 1

For operating mode
acknowledgement,
see Tab. 4/3

Device
control
software

Load voltĆ
age apĆ
plied

MalfuncĆ
tion

Warning

Operation
enabled

Drive
enabled

SPOS
Byte 2

B7
REF

B6
STILL

B5
DEV

B4
MOV

B3
TEACH

B2
MC

B1
ACK

B0
HOLD

Byte 2

Drive refĆ
erenced

ShutĆ
down
warning

Following
error

Axis movĆ
ing

Teach
acknow−
ledgment

Motion
complete

Acknow−
ledge
start

ć

Record no. Byte 3: Acknowledgement of last started record.

RSB
Byte 4

B7
ć

B6
ć

B5
XLIM

B4
VLIM

B3
RCE

B2
COM1

B1
RCC

B0
RC1

Byte 4

ć

ć

Stroke
limit
reached

Speed
limit
reached

Error
switching
to next
record

Control
mode
acknow−
ledgement

All record
switching
executed

1. record
switch
executed

Primary
actual
value

Byte 5 ... 8: Dependent on the parameterisation: Actual position or actual force in the
configured system of units.