beautypg.com

2 casm sensor interface, Casm sensor interface – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 69

background image

3. Electrical installation

3−9

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

3.2.2

CASM sensor interface

The CASM sensor interface has an incoming (S1) axis interĆ
face. See section 3.2.

A corresponding input (S2) for connecting the specific posiĆ
tion measuring system is also available. See Tab. 3/6.

Drive

Position measuring
system

Sensor interface

Connecting cable to the
displacement encoder

DGCI

Permanently
integrated

ć (no sensor interface
required)

KVI−CP−3−...

DNCI

Integrated

CASM−S−D3−R7

Permanently connected to DNCI.

DNC

External,
MLO−POT−...−LWG

NEBC−P1W4−K−0,3−N−M12G5

DSMI

Integrated

NEBC−P1W4−K−0,3−N−M12G5

DGP(L)

External,
MLO−POT−...−TLF

CASM−S−D2−R3

NEBC A1W3 K 0 3 N M12G5

DNCM

External, mounted on
delivery

NEBC−A1W3−K−0,3−N−M12G5

Tab. 3/6: Overview of sensor interfaces and displacement encoder cables