Example – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 102
4. Commissioning
4−24
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Example
The following applies for all examples:
x: = not relevant
1/0 = Brake control
0 or 1 depending
on configuration
1. Step: Enable CMAX
In the first step, CMAX must be prepared for the record
execution:
Control bytes (step 1)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
ć
RESET
BRAKE
STOP
ENABLE
Byte 1
0
0
0
0
0
1/0
1
1
CPOS
ć
CLEAR
TEACH
JOGN
JOGP
HOM
START
HOLD
Byte 2
0
0
0
0
0
0
0
0
Record no. Record number of the record to be started, not yet relevant:
Byte 3
x
x
x
x
x
x
x
x
res.
Byte 4 ... 8: reserved (= 0)
CMAX acknowledgement: Check the ready status in the
status byte.
There must be no malfunction. There should be
no warning. SPOS.ACK must be 0.
Status bytes (step 1)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
SCON
OPM2
OPM1
FCT_MMI
24VL
FAULT
WARN
OPEN
ENABLED
Byte 1
0
0
0
1
0
x (0)
1
1
SPOS
REF
STILL
DEV
MOV
TEACH
MC
ACK
HOLD
Byte 2
1
x
x
x
x
x
0
0
Record no. Acknowledgement of last started record:
Byte 3
x
x
x
x
x
x
x
x
RSB
ć
ć
XLIM
VLIM
RCE
COM1
RCC
RC1
Byte 4
x
x
x
x
x
x
x
x
Primary
actual
value
Byte 5 ... 8: Acknowledgement of the actual value of the position or force in the
configured system of units.