beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 129

background image

5. Diagnostics and error handling

5−7

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

5.2.3

Error level and reset type: Classification according to effect and
acknowledgement

All malfunctions and warnings are classified according to
the effect (error level, Tab. 5/2) and the necessary action for
acknowledgement (reset type, Tab. 5/3).

Error level

Description

W

Warning

F1

Malfunction 1: Stop with stop ramp

F2

Malfunction 2: Controller disabled

FS

System error: System stopped

Tab. 5/2: Error levels

Reset type

Description

R

Reset: acknowledge only

F

Fix cause and reset: Remedy cause and acknowledge
any malfunctions

N

New initialisation: Restart the axis after acknowledging
the malfunction

Poff

Poff: Switch CMAX off

Tab. 5/3: Reset types

Additional information can be found in the CMAX communiĆ
cation profile" description.