Festo Контроллер позиционирования CPX-CMAX User Manual
Page 129
5. Diagnostics and error handling
5−7
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5.2.3
Error level and reset type: Classification according to effect and
acknowledgement
All malfunctions and warnings are classified according to
the effect (error level, Tab. 5/2) and the necessary action for
acknowledgement (reset type, Tab. 5/3).
Error level
Description
W
Warning
F1
Malfunction 1: Stop with stop ramp
F2
Malfunction 2: Controller disabled
FS
System error: System stopped
Tab. 5/2: Error levels
Reset type
Description
R
Reset: acknowledge only
F
Fix cause and reset: Remedy cause and acknowledge
any malfunctions
N
New initialisation: Restart the axis after acknowledging
the malfunction
Poff
Poff: Switch CMAX off
Tab. 5/3: Reset types
Additional information can be found in the CMAX communiĆ
cation profile" description.