beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 91

background image

4. Commissioning

4−13

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

6. Parameterise application data and download it to the

CMAX:

ć

Mass

ć

Supply pressure

ć

Mounting position

This application data is the basis for configuring the conĆ
troller.

7. Set the other parameters (e.g. software end positions,

record list, ...) and download them to the CMAX.

8. Switch on the compressed air supply.

9. Carry out the movement test:

10. Only with incremental position measuring system: Carry

out homing.

11. Carry out identification run.

12. Carry out a test run.

After commissioning the positioning system (see suppleĆ
mental CMAX communication profile" description):

13. Configure the CPX bus node or CPX−FEC.

14. Check the control of the positioning system with the

CMAX.