Festo Контроллер позиционирования CPX-CMAX User Manual
Page 143

5. Diagnostics and error handling
5−21
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Malfunction group 4 ć System error A
CPX error group 104 (CPX−MMI: [System error A] )
Continued
No.
Type
1)
Error handling
Cause/description
Message
44
Teaching not possible
2)
(continued)
Specified record number
is not permissible during
teaching in record select
operating mode.
·
Correct record
number.
Error
level: F1
Reset: R
Parametrising control
mode of the selected reĆ
cord is not permissible
during teaching in record
select operating mode.
·
Correct the control
mode, correct the reĆ
cord number.
45
Commissioning function
or parameter value inĆ
valid
Invalid function number
at start of a commisĆ
sioning function in comĆ
missioning operating
mode.
3)
·
Correct the function
number.
Error
level: F1
Reset: R
At least one parameter
of the started commisĆ
sioning function had an
invalid value.
3)
·
Check parameter 1
and parameter 2 and
correct.
Movement test started
after there already was a
successfully executed
movement test.
·
Reset the movement
test first.
46
Start not possible with
active teach command
Commissioning operatĆ
ing mode: Starting a
commissioning function
during teaching is not
permissible.
·
Do not execute a
start during teaching.
End teaching first.
Error
level: F1
Reset: R
47
Start of tracking mode
requires MC
Starting tracking mode
during an active posiĆ
tioning job is not perĆ
missible.
·
End active positioning
job and wait for MoĆ
tion Complete"
(SPOX.MC=1).
Error
level: F1
Reset: R
1)
For the error level and reset type, see section 5.2.3.
2)
For an exact cause, see the diagnostic memory.
3)
See I/O data in the CMAX communication profile" description.