Festo Контроллер позиционирования CPX-CMAX User Manual
Page 103
4. Commissioning
4−25
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
2. Step: Specify record number
Control bytes (step 2)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
ć
RESET
BRAKE
STOP
ENABLE
Byte 1
0
0
0
0
0
1/0
1
1
CPOS
ć
CLEAR
TEACH
JOGN
JOGP
HOM
START
HOLD
Byte 2
0
0
0
0
0
0
0
0
Record no. Record number of the record to be started, example record 36 (0x24):
Byte 3
0
0
1
0
0
1
0
0
res.
Byte 4 ... 8: reserved (= 0)
No change in the status bytes:
Status bytes (step 2)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
SCON
OPM2
OPM1
FCT_MMI
24VL
FAULT
WARN
OPEN
ENABLED
Byte 1
0
0
0
1
0
0
1
1
SPOS
REF
STILL
DEV
MOV
TEACH
MC
ACK
HOLD
Byte 2
1
x
x
x
x
x
0
0
Record no. Acknowledgement of last started record.
Byte 3
x
x
x
x
x
x
x
x
RSB
ć
ć
XLIM
VLIM
RCE
COM1
RCC
RC1
Byte 4
x
x
x
x
x
x
x
x
Primary
actual
value
Byte 5 ... 8: Acknowledgement of the actual value of the position or force in the
configured system of units.
After setting the record number, wait at least 1 bus cycle
(recommendation: 1 PLC cycle) so that the record number has
definitely been transmitted to the CMAX before starting.