1 error numbers on the cpx terminal, Error numbers on the cpx terminal – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 128

5. Diagnostics and error handling
5−6
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5.2.1
Error numbers on the CPX terminal
All CMAX malfunctions are also signalled as CPX error
messages 10x (100 ... 109). These can be evaluated via
the CPX nodes, e.g. via the I/O diagnostic interface.
Function number
Module diagnostic data
2008+m*4+1
Module error number (CO error)
5.2.2
Malfunction groups: Classification according to the cause
CMAX malfunctions and warnings are organised into groups.
The first digit indicates the group and the second digit indiĆ
cates the cause.
When reading the malfunction via the function number of the
CPX node, the CPX error number is always displayed. The last
digit corresponds to the CMAX malfunction group (first digit
of the CMAX malfunction number).
CMAX malfunction groups and CPX error numbers
Group
Description
CPX error
CPX error text (MMI, configuration software)
0
Configuration error
100
[Configuration error]
1
Execution error
101
[Execution error]
2
Positioning record error
102
[Record error]
3
Regulation error
103
[Control error]
4
System error A
104
[System error A]
5
System error B
105
[System error B]
6
Valve error
106
[Error in valve]
7
Controller error
107
[Controller error]
8
Displacement encoder
error
108
[Encoder error]