beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 148

background image

5. Diagnostics and error handling

5−26

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

Malfunction group 7 ć Controller error

CPX error group 107 (CPX−MMI: [Controller error] )

No.

Message

Cause/description

Error handling

Type

1)

72

System software failure

Internal software error
(firmware).

·

If possible, read
out the diagnostic
memory, save the
project and archive it.

·

Switch the controller
on and off and see
whether the error
occurs again.

·

Contact Support.

Error level: FS
Reset: Poff

73

Controller hardware
defective

No communication with
CMAX possible. Error is
only indicated on the disĆ
play.

·

Exchange CMAX.

Error level: FS
Reset: Poff

74

No firmware

No firmware. No comĆ
munication is possible via
the fieldbus.

·

Firmware download
with FCT.

Error level: FS
Reset: Poff

75

User data damaged

Inconsistent user data.

·

Carry out data reset
and put axis back into
operation.

Error level: F2
Reset: N

76

Watchdog error:
Possible data loss
Data reset required

Internal watchdog error.

·

Carry out data reset
and put axis back into
operation.

·

Contact Support.

Error level: F2
Reset: F

1)