beautypg.com

Festo Контроллер позиционирования CPX-CMAX User Manual

Page 134

background image

5. Diagnostics and error handling

5−12

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

Malfunction group 2 ć Position record error

CPX error group 102 (CPX−MMI: [Record error] )

No.

Message

Cause/description

Error handling

Type

1)

21

Invalid record number

At the start there was
an invalid record
number (0 or > 64).

·

Check the record
number and correct
(first transfer record
number, then starting
edge).

Error
level: F1
Reset: R

22

Record is not configured

Called record was not
configured and does not
contain valid positioning
data.

·

Check record and
parameterise.

Error
level: F1
Reset: R

23

Position set is locked

The called record is not
enabled for execution.

·

Check the positioning
record and enable.

Error
level: F1
Reset: R

24

Record switching is not
possible

The demanded switchĆ
ing condition is invalid.

·

Check the switching
condition and correct.

Error
level: F1
Reset R

Switching parameterĆ
ised in record 64.

·

Remove switching
condition in record 64
and correct record
list, if necessary.

Reset: R

The selected switching
condition is not
permissible when using
a DSMI. The DSMI does
not support force
control.

·

Correct the switching
condition.

The selected switching
conditions are only alĆ
lowed in a positioning
record with force conĆ
trol.

·

Check the positioning
record and correct.

1)

For the error level and reset type, see section 5.2.3.