2 filter regulator, Filter regulator, Section 2.6.2 – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 54
2. Fitting and pneumatic installation
2−24
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
2.6.2
Filter regulator
·
Use a filter regulator consisting of a compressed air filter
and a regulating valve (e.g. LFR−...−D−... with 5
ìm filter
cartridge) in conjunction with a soft−start valve (e. g. HEL):
ć
without lubricator
ć
with a 5 Ģm filter
ć
with sufficiently large standard nominal flow rate
corresponding to the air requirement of the connected
drive during positioning. Reference value: twice the stanĆ
dard nominal flow rate of the valve (type VPWP), e.g.:
Valve (fitting)
Filter regulator
VPWP−2−... (M5)
LFR−1/8−D−5M−MINI or
MS4−LFR−1/4−D7−CRM−AS
VPWP−4−... (1/8)
LFR−1/8−D−5M−MINI or
MS4−LFR−1/4−D7−CRM−AS
VPWP−6−... (1/8)
LFR−1/4−D−5M−MINI or
MS4−LFR−1/4−D7−CRM−AS
VPWP−8−... (1/4)
LFR−3/8−D−5M−MIDI or
MS6−LFR−1/4−D7−CRM−AS
VPWP−10−... (3/8)
LFR−3/4−D−5M−MAXI or
MS6−LFR−3/8−D7−CRM−AS
Tab. 2/9: Selection of filter regulator
·
Use a fine filter or micro filter if you cannot avoid slight oil
mist from the compressed air supply.