Required software versions for the cpx nodes – Festo Контроллер позиционирования CPX-CMAX User Manual
Page 13
Contents and general safety instructions
XI
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Required software versions for the CPX nodes
Particular software versions for the CPX node are required for
operating the CMAX (versions as of August 2009):
CPX node
Required version
1)
Use
Special features
2)
CPX−FEC
From Revision 18 (R18)
On request
Ĉ Max. 8 CMAX modules
CPX−FB6 (Interbus)
From Revision 22 (R22)
On request
Ĉ Max. 1 CMAX module
CPX−FB11 (DeviceNet)
From Revision 20 (R20)
Suitable
Ĉ Max. 8 CMAX modules
CPX−FB13 (PROFIBUS−DP)
From Revision 23 (R23)
Suitable
Ĉ Max. 8 CMAX modules
Ĉ Acyclic services, DPV1
(then max.
7 CMAX modules)
CPX−FB14 (CANopen)
From Revision 20 (R20)
On request
Ĉ Max. 3 CMAX modules
CPX−FB23 (CC link)
From Revision 19 (R19)
On request
Ĉ Max. 8 CMAX modules
CPX−FB32 (Ethernet/IP)
From Revision 14 (R14)
On request
Ĉ Max. 8 CMAX modules
CPX−FB33 (PROFINET, M12)
From Revision 7 (R7)
On request
Ĉ Max. 8 CMAX modules
CPX−FB34 (PROFINET, RJ45)
From Revision 7 (R7)
On request
Ĉ Max. 8 CMAX modules
CPX−FB38 (EtherCAT)
All
On request
Ĉ Max. 8 CMAX modules
CPX−CEC
In preparation
On request
Ĉ Max. 8 CMAX modules
1)
Revisions version (Rev...) see name plate. Older revisions are not suitable for use with CMAX and
cannot lead to the intended behaviour.
2)
Depending on the CPX node functions used, the address range and therefore the maximum number
of modules can be further restricted, if necessary.
Tab. 0/1: Overview CPX nodes
Please also observe the notes on the software version in the
documentation for the CPX node.
To commission the CMAX, you will require the Festo configurĆ
ation tool with a CMAX plug−in. You can find this on the Festo
website at:
è
www.festo.com ˛ Downloads ˛ Download Area:
Software, drivers and firmware ˛ Enter search term: CMAX