4. Commissioning

4−32

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

1. Step: Enable CMAX

In the first step, CMAX must be prepared for direct mode:

Allocation of the control bytes (step 1)

Bit

B7

B6

B5

B4

B3

B2

B1

B0

CCON

OPM2

OPM1

LOCK

ć

RESET

BRAKE

STOP

ENABLE

Byte 1

0

1

0

0

0

1/0

1

1

CPOS

ć

CLEAR

TEACH

JOGN

JOGP

HOM

START

HOLD

Byte 2

0

0

0

0

0

0

0

0

CDIR

ć

FAST

XLIM

VLIM

CONT

COM2

COM1

ABS

Byte 3

0

1

0

0

0

0

0

0

Secondary
setpoint

Byte 4: Setpoint value of the speed: in percentage of the specified value Speed in direct
mode" (PNU540): not yet relevant.

Primary
setpoint

Byte 5 ... 8: Setpoint value of the position or force in the configured system of units:
not yet relevant.

CMAX acknowledgement: Check the ready status in the
status byte.

There must be no malfunction. There should be

no warning. SPOS.ACK must be 0.

Allocation of the status bytes (step 1)

Bit

B7

B6

B5

B4

B3

B2

B1

B0

SCON

OPM2

OPM1

FCT_MMI

24VL

FAULT

WARN

OPEN

ENABLED

Byte 1

0

1

0

1

0

x (0)

1

1

SPOS

REF

STILL

DEV

MOV

TEACH

MC

ACK

HOLD

Byte 2

1

x

x

x

x

x

0

0

SDIR

ć

FAST

XLIM

VLIM

CONT

COM2

COM1

ABS

Byte 3

x

x

x

x

x

x

x

x

Secondary
actual
value

Byte 4: Acknowledgement of the actual value of the speed in percentage of the set value
Speed in direct mode" (PNU540).

Primary
actual
value

Byte 5 ... 8: Acknowledgement of the actual value of the position or force in the
configured system of units.